We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

MSC Up To 2022 Part 4 - (149630 Products)


Schneider Electric - 23 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78mm Deep x 89mm High x 45mm Wide


Item #: 69526713
Brand: Schneider Electric
Model #: GV2ME21
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 23
Number of Poles 3
Breaking Capacity 15 kA @ 400/415 VAC; 3 kA @ 690 VAC; 4 kA @ 500 VAC; 50 kA @ 230/240 VAC; 6 kA @ 440 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Mounting Type Bolt-on; Clip
Voltage 690 VAC @ 50/60 Hz
Durability 100000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 78
Overall Height (mm) 89
Overall Width (mm) 45
For Use With TeSys GV2
Standards Met ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL

$279.26

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 1.60 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78mm Deep x 89mm High x 45mm Wide


Item #: 56828718
Brand: Schneider Electric
Model #: GV2RT06
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 1.60
Number of Poles 3
Breaking Capacity 100 kA @ 220/230 VAC; 100 kA @ 400/415 VAC; 100 kA @ 440 VAC; 100 kA @ 500 VAC; 100 kA @ 690 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Mounting Type Bolt-on; Clip
Voltage 690 VAC @ 50/60 Hz
Durability 100000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 78
Overall Height (mm) 89
Overall Width (mm) 45
For Use With TeSys GV2
Standards Met ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL

$278.92

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 2.50 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78mm Deep x 89mm High x 45mm Wide


Item #: 56805930
Brand: Schneider Electric
Model #: GV2ME076
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 2.50
Number of Poles 3
Breaking Capacity 100 kA @ 230/240 VAC; 100 kA @ 400/415 VAC; 100 kA @ 440 VAC; 100 kA @ 500 VAC; 3 kA @ 690 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Bolt-on; Clip
Voltage 690 VAC @ 50/60 Hz
Durability 100000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 78
Overall Height (mm) 89
Overall Width (mm) 45
For Use With TeSys GV2
Standards Met ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL

$278.92

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 1.60 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78mm Deep x 101mm High x 45mm Wide


Item #: 56805955
Brand: Schneider Electric
Model #: GV2ME063
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 1.60
Number of Poles 3
Breaking Capacity 100 kA @ 230/240 VAC; 100 kA @ 400/415 VAC; 100 kA @ 440 VAC; 100 kA @ 500 VAC; 100 kA @ 690 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Spring
Mounting Type Bolt-on; Clip
Voltage 690 VAC @ 50/60 Hz
Durability 100000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 78
Overall Height (mm) 101
Overall Width (mm) 45
For Use With TeSys GV2
Standards Met ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL

$278.92

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 8 Amp, 600 VAC, 3 Pole, DIN Rail Mounted, Panel Mount Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78-1/2mm Deep x 89mm High x 45mm Wide


Item #: 56828700
Brand: Schneider Electric
Model #: GV2RT03
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 8
Number of Poles 3
Breaking Capacity 100 kA @ 220/230 VAC; 100 kA @ 400/415 VAC; 100 kA @ 440 VAC; 100 kA @ 500 VAC; 100 kA @ 690 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Mounting Type DIN Rail Mounted; Panel Mount
Voltage 600 VAC
Durability 100000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 78-1/2
Overall Height (mm) 89
Overall Length (mm) 44-1/2
Overall Width (mm) 45
For Use With Motor Operators
Standards Met ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL
Reset Actuator Type Rocker Switch

$278.92

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 2.50 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78mm Deep x 89mm High x 45mm Wide


Item #: 56805872
Brand: Schneider Electric
Model #: GV2RT07
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 2.50
Number of Poles 3
Breaking Capacity 100 kA @ 220/230 VAC; 100 kA @ 400/415 VAC; 100 kA @ 440 VAC; 100 kA @ 500 VAC; 3 kA @ 690 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Mounting Type Bolt-on; Clip
Voltage 690 VAC @ 50/60 Hz
Durability 100000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 78
Overall Height (mm) 89
Overall Width (mm) 45
For Use With TeSys GV2
Standards Met ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL

$278.92

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 10 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78mm Deep x 89mm High x 45mm Wide


Item #: 56805922
Brand: Schneider Electric
Model #: GV2ME146
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 10
Number of Poles 3
Breaking Capacity 10 kA @ 500 VAC; 100 kA @ 230/240 VAC; 100 kA @ 400/415 VAC; 15 kA @ 440 VAC; 3 kA @ 690 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Bolt-on; Clip
Voltage 690 VAC @ 50/60 Hz
Durability 100000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 78
Overall Height (mm) 89
Overall Width (mm) 45
For Use With TeSys GV2
Standards Met ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL

$278.92

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 1.60 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78mm Deep x 89mm High x 45mm Wide


Item #: 56828676
Brand: Schneider Electric
Model #: GV2ME066
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 1.60
Number of Poles 3
Breaking Capacity 100 kA @ 230/240 VAC; 100 kA @ 400/415 VAC; 100 kA @ 440 VAC; 100 kA @ 500 VAC; 100 kA @ 690 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Bolt-on; Clip
Voltage 690 VAC @ 50/60 Hz
Durability 100000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 78
Overall Height (mm) 89
Overall Width (mm) 45
For Use With TeSys GV2
Standards Met ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL

$278.92

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 1 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78mm Deep x 101mm High x 45mm Wide


Item #: 56828684
Brand: Schneider Electric
Model #: GV2ME053
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 1
Number of Poles 3
Breaking Capacity 100 kA @ 230/240 VAC; 100 kA @ 400/415 VAC; 100 kA @ 440 VAC; 100 kA @ 500 VAC; 100 kA @ 690 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Spring
Mounting Type Bolt-on; Clip
Voltage 690 VAC @ 50/60 Hz
Durability 100000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 78
Overall Height (mm) 101
Overall Width (mm) 45
For Use With TeSys GV2
Standards Met ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL

$278.92

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 1 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78mm Deep x 89mm High x 45mm Wide


Item #: 56805880
Brand: Schneider Electric
Model #: GV2RT05
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 1
Number of Poles 3
Breaking Capacity 100 kA @ 220/230 VAC; 100 kA @ 400/415 VAC; 100 kA @ 440 VAC; 100 kA @ 500 VAC; 100 kA @ 690 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Mounting Type Bolt-on; Clip
Voltage 690 VAC @ 50/60 Hz
Durability 100000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 78
Overall Height (mm) 89
Overall Width (mm) 45
For Use With TeSys GV2
Standards Met ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL

$278.92

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 13 Amp, 600 VAC, 3 Pole, DIN Rail Mounted, Panel Mount Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78-1/2mm Deep x 89mm High x 45mm Wide


Item #: 56805898
Brand: Schneider Electric
Model #: GV2RT04
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 13
Number of Poles 3
Breaking Capacity 100 kA @ 220/230 VAC; 100 kA @ 400/415 VAC; 100 kA @ 440 VAC; 100 kA @ 500 VAC; 100 kA @ 690 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Mounting Type DIN Rail Mounted; Panel Mount
Voltage 600 VAC
Durability 100000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 78-1/2
Overall Height (mm) 89
Overall Length (mm) 44-1/2
Overall Width (mm) 45
For Use With Motor Operators
Standards Met ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL
Reset Actuator Type Rocker Switch

$278.92

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 80 Amp, 240 VAC, 2 Pole, Panel Mount Miniature Circuit Breaker - 12-2/0 AWG


Item #: 69531929
Brand: Square D
Model #: QOU280
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 80
Number of Poles 2
Terminal Connection Type Box Lugs
Mounting Type Panel Mount
Voltage 240 VAC
Wire Size (AWG) 12-2/0
Standards Met CSA; IEC; RoHS Compliant; UL Listed

$278.18

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Leviton - 4 Outlets, 125 VAC15 Amps, 15' Cord, Surge Power Outlet Strip - Wall/Surface Mount, 5-20 NEMA Configuration, 1' Strip, UL 60601-1


Item #: 60953460
Brand: Leviton
Model #: 5304M-1S5
Exact Tooling IR#: 04

Product Specifications
Amperage 15
Voltage 125 VAC
Number of Outlets 4
Material Steel
Mounting Type Wall/Surface
Strip Length (Feet) 1
Strip Length (Decimal Inch) 11.9300
Strip Length (Inch) 11
Cord Length (Feet) 15
NEMA Configuration 5-20
Overall Depth (Decimal Inch) 2.6000
Color White
Recommended Environment Hospital
Joules 644
Standards Met UL 60601-1
Protection Type Surge
Trip Reset Manual

$277.31

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Sola/Hevi-Duty - 45 Watt, 9 Amp, 100 VAC, 120 VAC, 220 VAC, 230 VAC, 240 VAC Input, 5 VDC Output, Power Supply - Screw Terminal Connection, 1 Output, 7 Inch Wide x 2-3/4 Inch Deep x 4.87 Inch High, 32 to 122°F


Item #: 76042662
Brand: Sola/Hevi-Duty
Model #: SLS-05-090-1T
Exact Tooling IR#: 04

Product Specifications
Mounting Type Panel
Output Wattage 45
Maximum Input Voltage 100 VAC; 120 VAC; 220 VAC; 230 VAC; 240 VAC
Minimum Input Voltage 100 VAC
Number of Outputs 1
Output Voltage 5 VDC
Output Amperage 9
Number of Phases 1
Connection Type Screw Terminal
Hold-up Time (ms) 50
Maximum Operating Temperature (F) 122
Minimum Operating Temperature (F) 32
Overall Height (mm) 123.70
Overall Height (Decimal Inch) 4.8700
Overall Width (mm) 178
Overall Width (Decimal Inch) 7
Overall Depth (mm) 70
Overall Depth (Decimal Inch) 2-3/4
Protection Features Over Voltage Protection; Overload Protection
Standards Met CE Certified IEC60950-1; CSA 60950-1; CSA C22.2; CSA ITE Certified; UL Recognized ITE- UL 60950-1

$277.94

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 1 & 3 Phase, 300VAC, Open Fused Cam & Disconnect Switch - Metal


Item #: 56643653
Brand: Square D
Model #: 9003K2H0138US
Exact Tooling IR#: 04

Product Specifications
Enclosure Type Open
Fused Fused
Number of Phases 1; 3
Amperage 12
Voltage 300 VAC
Horsepower at 1 Phase 0.5 @ 110-120 V; 1 @ 200-208 V; 1 @ 220-240 V
Horsepower at 3 Phase 1.5 @ 110-120 V; 2 @ 200-208 V; 3 @ 220-240 V
Overall Depth (mm) 82.50
Material Metal
Ingress Protection Rating IP20; IP40; IP65
Overall Height (mm) 50.00
Overall Width (mm) 45.00
Standards Met CSA File No. LR44087; IEC 60947-3; IEC 60947-5-1; UL File No. E164864; VDE 0660

$276.99

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 1 & 3 Phase, 300VAC, Open Fused Cam & Disconnect Switch - Metal


Item #: 56674468
Brand: Square D
Model #: 9003K2H0113US
Exact Tooling IR#: 04

Product Specifications
Enclosure Type Open
Fused Fused
Number of Phases 1; 3
Amperage 12
Voltage 300 VAC
Horsepower at 1 Phase 0.5 @ 110-120 V; 1 @ 200-208 V; 1 @ 220-240 V
Horsepower at 3 Phase 1.5 @ 110-120 V; 2 @ 200-208 V; 3 @ 220-240 V
Overall Depth (mm) 82.50
Material Metal
Ingress Protection Rating IP20; IP40; IP65
Overall Height (mm) 50.00
Overall Width (mm) 45.00
Standards Met CSA File No. LR44087; IEC 60947-3; IEC 60947-5-1; UL File No. E164864; VDE 0660

$276.99

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 1 & 3 Phase, 300VAC, Open Fused Cam & Disconnect Switch - Metal


Item #: 56643216
Brand: Square D
Model #: 9003K2H0210US
Exact Tooling IR#: 04

Product Specifications
Enclosure Type Open
Fused Fused
Number of Phases 1; 3
Amperage 12
Voltage 300 VAC
Horsepower at 1 Phase 0.5 @ 110-120 V; 1 @ 200-208 V; 1 @ 220-240 V
Horsepower at 3 Phase 1.5 @ 110-120 V; 2 @ 200-208 V; 3 @ 220-240 V
Overall Depth (mm) 82.50
Material Metal
Ingress Protection Rating IP20; IP40; IP65
Overall Height (mm) 50.00
Overall Width (mm) 45.00
Standards Met CSA File No. LR44087; IEC 60947-3; IEC 60947-5-1; UL File No. E164864; VDE 0660

$276.99

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 1 & 3 Phase, 300VAC, Open Fused Cam & Disconnect Switch - Metal


Item #: 56643661
Brand: Square D
Model #: 9003K2H0137US
Exact Tooling IR#: 04

Product Specifications
Enclosure Type Open
Fused Fused
Number of Phases 1; 3
Amperage 12
Voltage 300 VAC
Horsepower at 1 Phase 0.5 @ 110-120 V; 1 @ 200-208 V; 1 @ 220-240 V
Horsepower at 3 Phase 1.5 @ 110-120 V; 2 @ 200-208 V; 3 @ 220-240 V
Overall Depth (mm) 82.50
Material Metal
Ingress Protection Rating IP20; IP40; IP65
Overall Height (mm) 50.00
Overall Width (mm) 45.00
Standards Met CSA File No. LR44087; IEC 60947-3; IEC 60947-5-1; UL File No. E164864; VDE 0660

$276.99

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 1 & 3 Phase, 300VAC, Open Fused Cam & Disconnect Switch - Metal


Item #: 56674989
Brand: Square D
Model #: 9003K2H0296US
Exact Tooling IR#: 04

Product Specifications
Enclosure Type Open
Fused Fused
Number of Phases 1; 3
Amperage 12
Voltage 300 VAC
Horsepower at 1 Phase 0.5 @ 110-120 V; 1 @ 200-208 V; 1 @ 220-240 V
Horsepower at 3 Phase 1.5 @ 110-120 V; 2 @ 200-208 V; 3 @ 220-240 V
Overall Depth (mm) 82.50
Material Metal
Ingress Protection Rating IP20; IP40; IP65
Overall Height (mm) 50.00
Overall Width (mm) 45.00
Standards Met CSA File No. LR44087; IEC 60947-3; IEC 60947-5-1; UL File No. E164864; VDE 0660

$276.99

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 1 & 3 Phase, 300VAC, Open Fused Cam & Disconnect Switch - Metal


Item #: 56643166
Brand: Square D
Model #: 9003K2H0223US
Exact Tooling IR#: 04

Product Specifications
Enclosure Type Open
Fused Fused
Number of Phases 1; 3
Amperage 12
Voltage 300 VAC
Horsepower at 1 Phase 0.5 @ 110-120 V; 1 @ 200-208 V; 1 @ 220-240 V
Horsepower at 3 Phase 1.5 @ 110-120 V; 2 @ 200-208 V; 3 @ 220-240 V
Overall Depth (mm) 82.50
Material Metal
Ingress Protection Rating IP20; IP40; IP65
Overall Height (mm) 50.00
Overall Width (mm) 45.00
Standards Met CSA File No. LR44087; IEC 60947-3; IEC 60947-5-1; UL File No. E164864; VDE 0660