Square D - 60 Amp, 600Y/347 VAC, 3 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC, 14 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG


Item #: 41393547
Brand: Square D
Model #: BDL36060
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 60
Number of Poles 3
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 277 VAC; 14 kA @ 600Y/347 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type Toggle Switch

$1,006.76

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 630 Amp, 690 VAC, 4 Pole, Fixed Mount Molded Case Compact Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 185mm Wide


Item #: 56741275
Brand: Square D
Model #: LV432877
Exact Tooling IR#: 04

Features and Benefits

Molded Case Compact Circuit Breakers are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. They are smaller than molded case circuit breakers in design.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Compact Circuit Breaker
Amperage 630
Number of Poles 4
Breaking Capacity 10 kA @ 660/690 VAC; 20 kA @ 525 VAC; 20 kA @ 600 VAC; 25 kA @ 500 VAC; 30 kA @ 440 VAC; 30 kA @ 480 VAC; 35 kA @ 480 VAC; 36 kA @ 380/415 VAC; 40 kA @ 220/240 VAC; 40 kA @ 240 VAC; 85 kA @ 240 VAC
Tripping Mechanism Electronic
Mounting Type Fixed Mount
Voltage 690 VAC
Durability 15000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -31
Overall Width (mm) 185
Standards Met EN/IEC 60947-2; NEMA AB1; UL 508
Reset Actuator Type Toggle Switch

$13,562.29

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Amp, 480Y/277 Volt, 2 Pole, Clip Mount C60BP - Branch Protection Circuit Breaker - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG


Item #: 46120796
Brand: Schneider Electric
Model #: M9F42203
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60BP - Branch Protection
Amperage 3
Number of Poles 2
Breaking Capacity 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 14 kA @ 240 VAC; 10 kA @ 125 VDC; 10 kA @ 480Y/277 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 480Y/277 V
Wire Size (AWG) 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 4.0600
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 1.4200
For Use With OEM Panel
Standards Met UL 489; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$273.88

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 50 Amp, 600Y/347 VAC, 3 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG


Item #: 41396755
Brand: Square D
Model #: BGL36050LU
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 50
Number of Poles 3
Breaking Capacity 65 kA @ 240 VAC; 35 kA @ 480 VAC; 18 kA @ 600Y/347 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Reset Actuator Type Toggle Switch

$1,496.25

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 300 Amp, 240 V, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 240 VAC Breaking Capacity


Item #: 49753411
Brand: Square D
Model #: Q4L3300
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 300
Number of Poles 3
Breaking Capacity 25 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 240 V
Standards Met CCC; CSA; IEC; UL Listed

$4,099.39

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Value Collection - Circuit Breakers Circuit Breaker Type: Type III Circuit Breaker Amperage: 150


Item #: 66438870
Brand: Value Collection
Exact Tooling IR#: 04

Product Specifications

Circuit Breakers; Circuit Breaker Type: Type III Circuit Breaker ; Amperage: 150 ; Tripping Mechanism: Manual ; Mounting Type: Flush Mount ; Reset Actuator Type: Button
Circuit Breaker Type Type III Circuit Breaker
Amperage 150
Tripping Mechanism Manual
Mounting Type Flush Mount
Reset Actuator Type Button

$70.33

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 40 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 136mm Deep x 132mm High x 55mm Wide


Item #: 69649127
Brand: Schneider Electric
Model #: GV3P18
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 40
Number of Poles 3
Breaking Capacity 100 kA @ 230/240 VAC; 100 kA @ 400/415 VAC; 12 kA @ 500 VAC; 50 kA @ 440 VAC; 6 kA @ 690 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Mounting Type Bolt-on; Clip
Voltage 690 VAC @ 50/60 Hz
Durability 50000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 136
Overall Height (mm) 132
Overall Width (mm) 55
For Use With TeSys GV3
Standards Met ATEX; Bureau Veritas; CCC; CSA; DNV; GL; GOST; IEC 60947-2; LROS; RINA; UL

$476.18

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 2 Amp, 125 VDC, 240 VAC, 60 VDC, 1 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 107mm High x 18mm Wide


Item #: 69528743
Brand: Schneider Electric
Model #: 60103
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 2
Number of Poles 1
Breaking Capacity 10 kA @ 120 VAC; 10 kA @ 240 VAC; 10 kA @ 60 VDC; 5 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Tunnel
Mounting Type DIN Rail Mount; Fixed Mount
Voltage 125 VDC; 240 VAC; 60 VDC
Durability 20000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (mm) 73
Overall Height (mm) 107
Overall Width (mm) 18
Standards Met CSA C22.2 No. 5.2; IEC 60947-2; UL 489
Reset Actuator Type Handle

$130.74

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 20 Amp, 500 VDC, 2 Pole, Clip Mount C60H-DC Circuit Breaker - Supplementary Protection for Direct Current - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4, 18-6, 18-8 AWG


Item #: 46117040
Brand: Schneider Electric
Model #: M9U21220
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60H-DC - Supplementary Protection for Direct Current
Amperage 20
Number of Poles 2
Breaking Capacity 20 kA @ 220 VDC; 10 kA @ 440 VDC; 6 kA @ 500 VDC; 5 kA @ 12-500 VDC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 500 VDC
Wire Size (AWG) 18-4; 18-6; 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 3.1900
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 1.4200
For Use With OEM Panel
Standards Met UL 1077; IEC; CCC
Reset Actuator Type Toggle Switch

$399.12

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 80 Amp, 440 VAC, 3 Pole, DIN Rail Mounted Miniature Circuit Breaker - Thermal Magnetic Trip, 15 kA at 375 VDC Breaking Capacity, 18-1 AWG, 73mm Deep x 81mm High x 81mm Wide


Item #: 56787484
Brand: Schneider Electric
Model #: A9N18512
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 80
Number of Poles 3
Breaking Capacity 15 kA @ 375 VDC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Tunnel
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-50
Wire Size (AWG) 18-1
Durability 5000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 2.8740
Overall Depth (mm) 73
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 81
Overall Width (Decimal Inch) 3.1900
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$648.55

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 25 Amp, 480Y/277 Volt, 2 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG


Item #: 46117875
Brand: Schneider Electric
Model #: M9F21225
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60SP - Supplementary Protection
Amperage 25
Number of Poles 2
Breaking Capacity 14 kA @ 240 VAC; 10 kA @ 480Y/277 VAC; 10 kA @ 125 VDC; 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 480Y/277 V
Wire Size (AWG) 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 3.1900
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 1.4200
For Use With OEM Panel
Standards Met UL 1077; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$221.97

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 25 Amp, 277 Volt, 1 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG


Item #: 46109559
Brand: Schneider Electric
Model #: M9F22125
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60SP - Supplementary Protection
Amperage 25
Number of Poles 1
Breaking Capacity 10 kA @ 277 VAC; 14 kA @ 240 VAC; 14 kA @ 120 VAC; 10 kA @ 65 VDC; 3 kA @ 415 VAC; 10 kA @ 240 VAC; 20 kA @ 60 VDC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 277 V
Wire Size (AWG) 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 3.1900
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 0.7100
For Use With OEM Panel
Standards Met UL 1077; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$102.83

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 250 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56749476
Brand: Square D
Model #: JGL36250SALU
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 250
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$8,943.15

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 200 Amp, 250 VDC, 600 VAC, 2 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56744501
Brand: Square D
Model #: JDL26200LY
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 2
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$3,539.05

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 175 Amp, 250 VDC, 600 VAC, 2 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 4-4/0 AWG


Item #: 56743404
Brand: Square D
Model #: JJL26175
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 175
Number of Poles 2
Breaking Capacity 100 kA @ 240 VAC; 20 kA @ 250 VDC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 4-4/0

$7,600.43

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 25 Amp, 125 VDC, 240 VAC, 60 VDC, 1 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 81mm High x 18mm Wide


Item #: 69659530
Brand: Schneider Electric
Model #: 60114
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 25
Number of Poles 1
Breaking Capacity 10 kA @ 120 VAC; 10 kA @ 240 VAC; 10 kA @ 60 VDC; 5 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Tunnel
Mounting Type DIN Rail Mount; Fixed Mount
Voltage 125 VDC; 240 VAC; 60 VDC
Durability 20000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -13
Overall Depth (mm) 73
Overall Height (mm) 81
Overall Width (mm) 18
Standards Met CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type Toggle Switch

$114.58

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 10 Amp, 120/240 VAC, 1 Pole, DIN Rail Mounted, Flush Mount, Surface Mount Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 120/240 VAC Breaking Capacity, 14-2 (Aluminum), 14-2 (Copper) AWG, 74mm Deep x 103mm High x 19mm Wide


Item #: 56837396
Brand: Square D
Model #: QOUR110
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 10
Number of Poles 1
Breaking Capacity 10 kA @ 120/240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type DIN Rail Mounted; Flush Mount; Surface Mount
Voltage 120/240 VAC
Wire Size (AWG) 14-2 (Aluminum); 14-2 (Copper)
Overall Depth (Decimal Inch) 2.9200
Overall Depth (mm) 74
Overall Height (mm) 103
Overall Height (Decimal Inch) 4.0500
Overall Width (mm) 19
Overall Width (Decimal Inch) 3/4
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; UL Listed
Reset Actuator Type Toggle Switch

$66.74

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 6 Amp, 440 VAC, 1 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4 AWG, 76mm Deep x 81mm High x 18mm Wide


Item #: 56838204
Brand: Schneider Electric
Model #: M9F14106
Exact Tooling IR#: 04

Features and Benefits

Magnetic tripping mechanisms are designed with a solenoid (electromagnet), which will quickly disconnect in case of a short circuit or overload. They are not greatly affected by extreme environmental conditions, but are sensitive to low-overloads.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 6
Number of Poles 1
Breaking Capacity 15 kA @ 230/240 VAC; 30 kA @ 130 VAC; 4 kA @ 400/415 VAC
Tripping Mechanism Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-25
Wire Size (AWG) 18-4
Durability 10000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 18
Overall Width (Decimal Inch) 0.7100
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$174.37

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 30 Amp, 347 VAC, 1 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC, 14 kA at 347 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41398751
Brand: Square D
Model #: BDA160301
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 30
Number of Poles 1
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 277 VAC; 14 kA @ 347VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 347 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type Toggle Switch

$419.75

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 1 Amp, 125 VDC, 240 VAC, 60 VDC, 1 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 277 VAC Breaking Capacity, 73mm Deep x 107mm High x 18mm Wide


Item #: 69532216
Brand: Schneider Electric
Model #: 60101
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 1
Number of Poles 1
Breaking Capacity 10 kA @ 277 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Tunnel
Mounting Type DIN Rail Mount; Fixed Mount
Voltage 125 VDC; 240 VAC; 60 VDC
Durability 20000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -13
Overall Depth (mm) 73
Overall Height (mm) 107
Overall Width (mm) 18
Standards Met CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type Toggle Switch

$121.73

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It