Square D - 30 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 69647691
Brand: Square D
Model #: HGL36030
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 30
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 20 kA @ 250 VDC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0
Standards Met RoHS Compliant

$1,848.48

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 200 Amp, 600 VAC/VDC, 3 Pole Nonfused Safety Switch - NEMA 12, 3, 3R, 4 & 4X, 50 hp at 600 VAC, 50 hp at 600 VDC (Single Phase), 150 hp at 600 VAC, 50 hp at 600 VDC (Triple Phase)


Item #: 56771975
Brand: Square D
Model #: HU364DSEI
Exact Tooling IR#: 04

Product Specifications
NEMA Enclosure Rating 12; 3; 3R; 4; 4X
Fused NonFused
Number of Poles 3
Amperage 200
Voltage 600 VAC/VDC
Horsepower at 1 Phase 50 @ 600 VAC, 50 @ 600 VDC
Horsepower at 3 Phase 150 @ 600 VAC, 50 @ 600 VDC
Contact Configuration NO/NC
Material Stainless Steel
Standards Met UL Listed

$12,263.95

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Cam and Disconnect Switch Shaft Extension - For Use with GS


Item #: 56807712
Brand: Schneider Electric
Model #: GS2AE5
Exact Tooling IR#: 04

Product Specifications
Switch Accessory Type Shaft Extension
For Use With GS

$51.60

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Tripp-Lite - 12 Outlets, 120 VAC15 Amps, 8' Cord, Power Outlet Strip - Floor, Keyhole Mount, 5-15 NEMA Configuration, 12.04" Strip


Item #: 41633587
Brand: Tripp-Lite
Model #: TLP1208SAT
Exact Tooling IR#: 04

Product Specifications
Amperage 15
Voltage 120 VAC
Number of Outlets 12
Material Plastic
Mounting Type Floor; Keyhole
Strip Length (Decimal Inch) 12.0400
Cord Length (Feet) 8
NEMA Configuration 5-15
Overall Depth (Decimal Inch) 12.0400
Color White
Overall Height (Decimal Inch) 1.5100
Overall Width (Decimal Inch) 4.8600
Trip Reset Manual

$65.24

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 60 Amp, 347 VAC, 1 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 V, 18 kA at 347 VAC, 35 kA at 277 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41394156
Brand: Square D
Model #: BGA160601
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 60
Number of Poles 1
Breaking Capacity 65 kA @ 240 V; 18 kA @ 347 VAC; 35 kA @ 277 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 347 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type Toggle Switch

$605.96

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Tripp-Lite - 16 Outlets, 120 VAC15 Amps, 15' Cord, Power Outlet Strip - Floor, Keyhole Mount, 5-15 NEMA Configuration, 48" Strip


Item #: 04071700
Brand: Tripp-Lite
Model #: SS7415-15
Exact Tooling IR#: 04

Product Specifications
Amperage 15
Voltage 120 VAC
Number of Outlets 16
Material Plastic
Mounting Type Floor; Keyhole
Strip Length (Decimal Inch) 48
Cord Length (Feet) 15
NEMA Configuration 5-15
Overall Depth (Decimal Inch) 48
Color White
Overall Height (Decimal Inch) 1-1/4
Overall Width (Decimal Inch) 1.6200
Trip Reset Manual

$140.64

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Tripp-Lite - 8 Outlets, 120 VAC15 Amps, 8' Cord, Power Outlet Strip - Floor, Keyhole Mount, 5-15 NEMA Configuration, 9.55" Strip


Item #: 41633488
Brand: Tripp-Lite
Model #: TLP808NETG
Exact Tooling IR#: 04

Product Specifications
Amperage 15
Voltage 120 VAC
Number of Outlets 8
Material Plastic
Mounting Type Floor; Keyhole
Strip Length (Decimal Inch) 9.5500
Cord Length (Feet) 8
NEMA Configuration 5-15
Overall Depth (Decimal Inch) 9.5500
Color White
Overall Height (Decimal Inch) 1.5100
Overall Width (Decimal Inch) 4.8600
Trip Reset Manual

$157.64

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 400 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, 110mm Deep x 340mm High x 140mm Wide


Item #: 56765381
Brand: Square D
Model #: LGM36400U44X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 400
Number of Poles 3
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 4.3300
Overall Depth (mm) 110
Overall Height (mm) 340
Overall Height (Decimal Inch) 13.3800
Overall Width (mm) 140
Overall Width (Decimal Inch) 5.5100
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$13,957.68

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Wiremold - 8 Outlets, 120 Volts, 15 Amps, Power Outlet Strip - 2 Circuits, Raceway Mount, 5-15P NEMA Configuration, 6' Strip


Item #: 09847211
Brand: Wiremold
Model #: V20GBA609
Exact Tooling IR#: 04

Product Specifications
Amperage 15
Voltage 120 V
Number of Outlets 8
Material Steel
Mounting Type Raceway
Strip Length (Feet) 6
Cord Length (Feet) 0
NEMA Configuration 5-15P
Color Ivory
Number of Circuits 2
Outlet Spacing (mm) 229
Outlet Spacing (Inch) 9

$182.41

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Amp, 1 Pole, Backplate, Clip, DIN Rail Mount Circuit Protector - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 67mm Deep x 74mm High x 15mm Wide


Item #: 56829633
Brand: Schneider Electric
Model #: GB2CD08
Exact Tooling IR#: 04

Features and Benefits

Circuit protectors are designed for protecting relays, motors, heaters, transformers, solenoids and semiconductors from short circuiting. They protect by monitoring the flow of electricity and detecting any imbalances in the electrical device.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Circuit Protector
Amperage 3
Number of Poles 1
Breaking Capacity 1 kA @ 48 VDC; 1.5 kA @ 24 VDC; 10 kA @ 110 VAC; 3 kA @ 230/240 VAC
Tripping Mechanism Thermal-Magnetic
Mounting Type Backplate; Clip; DIN Rail Mount
Durability 8000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 67
Overall Height (mm) 74
Overall Width (mm) 15
Reset Actuator Type Toggle Switch

$80.60

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Tripp-Lite - 4 Outlets, 220/240 VAC 15 Amps, 6' Cord, 330J Power Outlet Strip - Floor, Keyhole Mount, 5-15 NEMA Configuration, 2-1/2" Strip


Item #: 41633314
Brand: Tripp-Lite
Model #: IB4-6/220
Exact Tooling IR#: 04

Product Specifications
Amperage 15
Voltage 220/240
Number of Outlets 4
Material Aluminum
Mounting Type Floor; Keyhole
Strip Length (Decimal Inch) 2-1/2
Cord Length (Feet) 6
NEMA Configuration 5-15
Overall Depth (Decimal Inch) 2-1/2
Color White
Overall Height (Decimal Inch) 3-1/2
Overall Width (Decimal Inch) 7
Joules 330
Trip Reset Manual

$97.25

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 30 Amp, 240 VAC, 3 Pole, Plug In Type BR Circuit Breaker - Magnetic Trip, 10 kA Breaking Capacity, 14-4 AWG


Item #: 00105346
Brand: Eaton Cutler-Hammer
Model #: BR330
Exact Tooling IR#: 04

Features and Benefits

Type BR circuuit breakers are used in load centers, panelboards, or similar devices. They are available in 1,2 or with 3 poles.
Magnetic tripping mechanisms are designed with a solenoid (electromagnet), which will quickly disconnect in case of a short circuit or overload. They are not greatly affected by extreme environmental conditions, but are sensitive to low-overloads.
Product Specifications
Circuit Breaker Type Type BR Circuit Breaker
Amperage 30
Number of Poles 3
Breaking Capacity 10 kA
Tripping Mechanism Magnetic
Mounting Type Plug-in
Voltage 240 VAC
Wire Size (AWG) 14-4
Standards Met NEC 2008; NEC 2011; NEC 2014; UL Listed 67

$398.13

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Tripp-Lite - 6 Outlets, 120 VAC15 Amps, 6' Cord, Power Outlet Strip - Floor, Keyhole Mount, 5-15 NEMA Configuration, 13" Strip


Item #: 54759477
Brand: Tripp-Lite
Model #: TLP606USB
Exact Tooling IR#: 04

Product Specifications
Amperage 15
Voltage 120 VAC
Number of Outlets 6
Material Plastic
Mounting Type Floor; Keyhole
Strip Length (Decimal Inch) 13
Cord Length (Feet) 6
NEMA Configuration 5-15
Overall Depth (Decimal Inch) 13
Color White
Overall Height (Decimal Inch) 1-1/4
Overall Width (Decimal Inch) 1.8700
Trip Reset Manual

$51.55

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

innovera - 6 Outlets, 120 Volts, 15 Amps, 4' Cord, Surge Power Outlet Strip - Floor Mount, 5-15R NEMA Configuration


Item #: 47007356
Brand: innovera
Model #: IVR71652
Exact Tooling IR#: 04

Product Specifications
Amperage 15
Voltage 120 V
Number of Outlets 6
Material Plastic
Mounting Type Floor
Cord Length (Feet) 4
NEMA Configuration 5-15R
Color White
Protection Type Surge

$31.58

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 60 Amp, 240 VAC, 2 Pole, Panel Mount Miniature Circuit Breaker - 14-2 AWG


Item #: 56788763
Brand: Square D
Model #: QOU2601042
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 60
Number of Poles 2
Terminal Connection Type Box Lugs
Mounting Type Panel Mount
Voltage 240 VAC
Wire Size (AWG) 14-2
For Use With Shunt Trip 12/24 VAC/VDC
Standards Met CSA; IEC; RoHS Compliant; UL Listed

$384.97

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 20/15 Amp, 120 VAC, 1 Pole, Plug In Type BD Duplex Circuit Breaker - Thermal Magnetic Trip, 10 kA Breaking Capacity, 14-4 AWG


Item #: 00105429
Brand: Eaton Cutler-Hammer
Model #: BD2015
Exact Tooling IR#: 04

Features and Benefits

Type BD duplex circuit breakers are designed to protect form overload and short circuits. They are not interchangeable with other breakers and they are for use in BR type panels. Type BD duplex breakers allow for the use of two single pole breakers in one space.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Type BD Duplex Circuit Breaker
Amperage 20/15
Number of Poles 1
Breaking Capacity 10 kA
Tripping Mechanism Thermal-Magnetic
Mounting Type Plug-in
Voltage 120 VAC
Wire Size (AWG) 14-4
Standards Met NEC 2008; NEC 2011; NEC 2014; UL Listed 67

$103.00

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Tripp-Lite - 8 Outlets, 120 VAC15 Amps, 12' Cord, Power Outlet Strip - Floor, Keyhole Mount, 5-15 NEMA Configuration, 1.57" Strip


Item #: 49026453
Brand: Tripp-Lite
Model #: TLM812SA
Exact Tooling IR#: 04

Product Specifications
Amperage 15
Voltage 120 VAC
Number of Outlets 8
Material Plastic
Mounting Type Floor; Keyhole
Strip Length (Decimal Inch) 1.5700
Cord Length (Feet) 12
NEMA Configuration 5-15
Overall Depth (Decimal Inch) 1.5700
Color White
Overall Height (Decimal Inch) 10.2600
Overall Width (Decimal Inch) 5.1300
Trip Reset Manual

$87.67

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 1 Phase, 480 Volt Input, 120 Volt Output, 150 VA, General Purpose Transformer - 1 NEMA Rating, Indoor


Item #: 54527361
Brand: Square D
Model #: 460R480
Exact Tooling IR#: 04

Features and Benefits

Single-phase refers to one phase line (coil) that connects to and runs voltage through the motor. Single phase lines are not as efficient as three-phase motors.
Product Specifications
Power Rating (VA) 150
Input Voltage 480
Output Voltage 120 V
Number of Phases 1
Recommended Environment Indoor
NEMA Enclosure Rating 1
Standards Met UL Listed

$1,812.14

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 20 Amp, 125 VDC, 240 VAC, 60 VDC, 1 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 107mm High x 36mm Wide


Item #: 69659472
Brand: Schneider Electric
Model #: 60147
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 20
Number of Poles 1
Breaking Capacity 10 kA @ 125 VDC; 10 kA @ 240 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 6 kA @ 440 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Tunnel
Mounting Type DIN Rail Mount; Fixed Mount
Voltage 125 VDC; 240 VAC; 60 VDC
Durability 20000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (mm) 73
Overall Height (mm) 107
Overall Width (mm) 36
Standards Met CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type Handle

$254.85

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 20 Amp, 480Y/277 Volt, 2 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG


Item #: 46110227
Brand: Schneider Electric
Model #: M9F22220
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60SP - Supplementary Protection
Amperage 20
Number of Poles 2
Breaking Capacity 14 kA @ 240 VAC; 10 kA @ 480Y/277 VAC; 10 kA @ 125 VDC; 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 480Y/277 V
Wire Size (AWG) 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 3.1900
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 1.4200
For Use With OEM Panel
Standards Met UL 1077; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$221.97

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It