We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

Lighting & Electrical Products - Power Distribution & Generation Equipment For Sale | Makers Industrial Supply - (9097 Products)


Square D - 25 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14-3/0 AWG, 87.4mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56746092
Brand: Square D
Model #: HJL36025T
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 25
Number of Poles 3
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4400
Overall Depth (mm) 87.40
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$3,171.32

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 35 Amp, 600Y/347 VAC, 3 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 100 kA at 240 VAC, 65 kA at 480 VAC, 25 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG


Item #: 41400375
Brand: Square D
Model #: BJL36035LU
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 35
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 65 kA @ 480 VAC; 25 kA @ 600Y/347 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type Toggle Switch

$1,917.87

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 50 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14-3/0 AWG, 87.4mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56746001
Brand: Square D
Model #: HJL36050T
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 50
Number of Poles 3
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4400
Overall Depth (mm) 87.40
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$3,171.32

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 20 Amp, 240 VAC, 3 Pole, Plug In Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA Breaking Capacity, 14-4 AWG, 2-3/8 Inch Deep x 2-15/16 Inch High x 3 Inch Wide


Item #: 04882494
Brand: Eaton Cutler-Hammer
Model #: HQP3020H
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 20
Number of Poles 3
Breaking Capacity 10 kA
Tripping Mechanism Thermal-Magnetic
Mounting Type Plug-in
Voltage 240 VAC
Wire Size (AWG) 14-4
Overall Depth (Inch) 2-3/8
Overall Height (Inch) 2-15/16
Overall Width (Inch) 3
Standards Met CSA Listed; Federal Specification W-C-375b; UL Listed 489

$679.57

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 7 Amp, 125 VDC, 240 VAC, 60 VDC, 1 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 107mm High x 36mm Wide


Item #: 56838840
Brand: Schneider Electric
Model #: 60142
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 7
Number of Poles 1
Breaking Capacity 10 kA @ 125 VDC; 10 kA @ 240 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 6 kA @ 440 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Tunnel
Mounting Type DIN Rail Mount; Fixed Mount
Voltage 125 VDC; 240 VAC; 60 VDC
Durability 20000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (mm) 73
Overall Height (mm) 107
Overall Width (mm) 36
Standards Met CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type Handle

$258.89

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 40 Amp, 600Y/347 VAC, 3 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600Y/347 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41384355
Brand: Square D
Model #: BGA36040
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 40
Number of Poles 3
Breaking Capacity 65 kA @ 240 VAC; 35 kA @ 480 VAC; 18 kA @ 600Y/347 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type Toggle Switch

$1,590.44

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 10 Amp, 2 Pole, DIN Rail Mount Standard Circuit Breaker - Multiple Breaking Capacity Ratings, 14-4 (Copper) AWG, 3 Inch Deep x 3.19 Inch High x 1.42 Inch Wide


Item #: 69659910
Brand: Schneider Electric
Model #: MG24131
Exact Tooling IR#: 04

Features and Benefits

Standard circuit breakers are resettable switches used for protecting electrical circuits from overloads or short circuits. They are designed to automatically detect and interrupt the electrical flow of a circuit if a problem occurs.
Product Specifications
Circuit Breaker Type Standard Circuit Breaker
Amperage 10
Number of Poles 2
Breaking Capacity 10 kA @ 240 VAC; 5 kA @ 480Y/277 VAC
Mounting Type DIN Rail Mount
Wire Size (AWG) 14-4 (Copper)
Overall Depth (Decimal Inch) 3
Overall Height (Decimal Inch) 3.1900
Overall Width (Decimal Inch) 1.4200
For Use With OEM Panel

$214.95

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 100 Amp, 440 VAC, 3 Pole, DIN Rail Mounted Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 18-1 AWG, 76mm Deep x 81mm High x 81mm Wide


Item #: 56787567
Brand: Schneider Electric
Model #: A9N18425
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 100
Number of Poles 3
Breaking Capacity 10 kA @ 440 VAC; 15 kA @ 375 VDC; 15 kA @ 400-415 VAC; 30 kA @ 230-240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-50
Wire Size (AWG) 18-1
Durability 5000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 81
Overall Width (Decimal Inch) 3.1900
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$648.55

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 4 Amp, 440 VAC, 3 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4 AWG, 76mm Deep x 81mm High x 54mm Wide


Item #: 56786759
Brand: Schneider Electric
Model #: M9F17204
Exact Tooling IR#: 04

Features and Benefits

Magnetic tripping mechanisms are designed with a solenoid (electromagnet), which will quickly disconnect in case of a short circuit or overload. They are not greatly affected by extreme environmental conditions, but are sensitive to low-overloads.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 4
Number of Poles 3
Breaking Capacity 20 kA @ 440 VAC; 25 kA @ 400-415 VAC; 50 kA @ 230-240 VAC
Tripping Mechanism Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-25
Wire Size (AWG) 18-4
Durability 10000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 54
Overall Width (Decimal Inch) 2.1300
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$463.02

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 4 Amp, 500 VDC, 2 Pole, Clip Mount C60H-DC Circuit Breaker - Supplementary Protection for Direct Current - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4, 18-6, 18-8 AWG


Item #: 46111365
Brand: Schneider Electric
Model #: M9U31204
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60H-DC - Supplementary Protection for Direct Current
Amperage 4
Number of Poles 2
Breaking Capacity 20 kA @ 220 VDC; 10 kA @ 440 VDC; 6 kA @ 500 VDC; 5 kA @ 12-500 VDC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 500 VDC
Wire Size (AWG) 18-4; 18-6; 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 3.1900
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 1.4200
For Use With OEM Panel
Standards Met UL 1077; IEC; CCC
Reset Actuator Type Toggle Switch

$399.12

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 2000 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 56768179
Brand: Square D
Model #: RGF36200CU63AE1
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 2000
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Electronic
Terminal Connection Type Screw
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 3/0
Standards Met CSA; IEC; UL Listed

$66,923.02

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 15 Amp, 600Y/347 VAC, 2 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC, 14 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG


Item #: 41393992
Brand: Square D
Model #: BDL26015LU
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 15
Number of Poles 2
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 277 VAC; 14 kA @ 600Y/347 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type Toggle Switch

$919.33

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 90 Amp, 347 VAC, 1 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC, 14 kA at 347 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41399015
Brand: Square D
Model #: BDA160901
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 90
Number of Poles 1
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 277 VAC; 14 kA @ 347VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 347 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type Toggle Switch

$492.48

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 18 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78mm Deep x 89mm High x 45mm Wide


Item #: 69526705
Brand: Schneider Electric
Model #: GV2ME20
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 18
Number of Poles 3
Breaking Capacity 100 kA @ 230/240 VAC; 15 kA @ 400/415 VAC; 3 kA @ 690 VAC; 6 kA @ 500 VAC; 8 kA @ 440 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Mounting Type Bolt-on; Clip
Voltage 690 VAC @ 50/60 Hz
Durability 100000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 78
Overall Height (mm) 89
Overall Width (mm) 45
For Use With TeSys GV2
Standards Met ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL

$274.00

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Carling Switch - 5 Amp, 277 VAC, 65 VDC, 1 Pole, Panel Mount Miniature Circuit Breaker - Hydraulic Magnetic Trip, 38.8mm Deep x 39.62mm High x 35.41mm Wide


Item #: 54076054
Brand: Carling Switch
Model #: MA1-B-34-450-1-
Exact Tooling IR#: 04

Features and Benefits

Hydraulic-magnetic tripping mechanisms are designed to be used in applications where temperatures and environmental conditions are extreme. They are quick to respond to overloads and cut-off power after a time-delay.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 5
Number of Poles 1
Tripping Mechanism Hydraulic-Magnetic
Terminal Connection Type Quick Connect
Mounting Type Panel Mount
Voltage 277 VAC; 65 VDC
Maximum Operating Temperature (F) 185
Minimum Operating Temperature (F) -40
Overall Depth (Decimal Inch) 1.5300
Overall Depth (mm) 38.80
Overall Height (mm) 39.62
Overall Height (Decimal Inch) 1.5600
Overall Width (mm) 35.41
Overall Width (Decimal Inch) 1.3940
Standards Met CSA Accepted under Class 3215 30File 047848 0 000; CSA C22.2 No. 235; EN 60934; TUV Certified EN60934 Under License No.R72040875; UL 1500 Guide PEQZ2 File E75596; UL 508 Guide CCN/NRNT2 File E148683; UL Listed 489A Guide CCN/DITT File E189195
Reset Actuator Type Handle

$25.08

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 125 Amp, 480Y/277 VAC, 2 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 480Y/277 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41399627
Brand: Square D
Model #: BDA24125Y1
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 125
Number of Poles 2
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 480Y/277VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 480Y/277 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type Toggle Switch

$1,118.84

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 80 Amp, 347 VAC, 1 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC, 14 kA at 347 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41399023
Brand: Square D
Model #: BDA160801
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 80
Number of Poles 1
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 277 VAC; 14 kA @ 347VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 347 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type Toggle Switch

$492.48

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 20 Amp, 250 VDC, 1 Pole, Clip Mount C60H-DC Circuit Breaker - Supplementary Protection for Direct Current - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4, 18-6, 18-8 AWG


Item #: 46117511
Brand: Schneider Electric
Model #: M9U31120
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60H-DC - Supplementary Protection for Direct Current
Amperage 20
Number of Poles 1
Breaking Capacity 10 kA @ 220 VDC; 6 kA @ 250 VDC; 20 kA @ 110 VDC; 5 kA @ 12-250 VDC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 250 VDC
Wire Size (AWG) 18-4; 18-6; 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 3.1900
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 0.7100
For Use With OEM Panel
Standards Met UL 1077; IEC; CCC
Reset Actuator Type Toggle Switch

$185.30

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 50 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56739451
Brand: Square D
Model #: HDL36050SA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 50
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$2,797.15

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 50 Amp, 240 VAC, 3 Pole, Panel Mount Miniature Circuit Breaker - 14-2 AWG


Item #: 56788532
Brand: Square D
Model #: QOU3501200
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 50
Number of Poles 3
Terminal Connection Type Box Lugs
Mounting Type Panel Mount
Voltage 240 VAC
Wire Size (AWG) 14-2
For Use With Auxiliary Switch 1A
Standards Met CSA; IEC; RoHS Compliant; UL Listed

$581.61

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It