We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

Lighting & Electrical Products - Power Distribution & Generation Equipment For Sale | Makers Industrial Supply - (9097 Products)


Schneider Electric - 63 Amp, 480Y/277 Volt, 2 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2, 18-3 AWG


Item #: 46118303
Brand: Schneider Electric
Model #: M9F21263
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60SP - Supplementary Protection
Amperage 63
Number of Poles 2
Breaking Capacity 10 kA @ 240 VAC; 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 5 kA @ 480Y/277 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 480Y/277 V
Wire Size (AWG) 18-2; 18-3
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 3.1900
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 1.4200
For Use With OEM Panel
Standards Met UL 1077; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$256.57

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 56743354
Brand: Square D
Model #: JJL36200C
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 20 kA @ 250 VDC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0
Standards Met RoHS Compliant

$10,607.36

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 6 Amp, 440 VAC, 2 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4 AWG, 76mm Deep x 81mm High x 36mm Wide


Item #: 49786858
Brand: Schneider Electric
Model #: M9F11206
Exact Tooling IR#: 04

Features and Benefits

Magnetic tripping mechanisms are designed with a solenoid (electromagnet), which will quickly disconnect in case of a short circuit or overload. They are not greatly affected by extreme environmental conditions, but are sensitive to low-overloads.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 6
Number of Poles 2
Breaking Capacity 10 kA @ 400-415 VAC; 20 kA @ 230-240 VAC; 6 kA @ 440 VAC
Tripping Mechanism Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-25
Wire Size (AWG) 18-4
Durability 10000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 36
Overall Width (Decimal Inch) 1.4200
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$269.84

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 125 Amp, 440 VAC, 2 Pole, DIN Rail Mounted Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 18-1 AWG, 76mm Deep x 81mm High x 54mm Wide


Item #: 56787492
Brand: Schneider Electric
Model #: A9N18503
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 125
Number of Poles 2
Breaking Capacity 10 kA @ 440 VAC; 15 kA @ 250 VDC; 15 kA @ 400-415 VAC; 30 kA @ 230-240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-50
Wire Size (AWG) 18-1
Durability 5000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 54
Overall Width (Decimal Inch) 2.1300
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$564.85

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 225 Amp, 600 V, 2 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings


Item #: 56757222
Brand: Square D
Model #: LAL26225
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 225
Number of Poles 2
Breaking Capacity 10 kA @ 125 VDC; 10 kA @ 250 VDC; 22 kA @ 600 VAC; 30 kA @ 480 VAC; 42 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 V
Standards Met CCC; CSA; IEC; UL Listed

$3,914.43

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 175 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 4-4/0 AWG


Item #: 56742901
Brand: Square D
Model #: JLL36175
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 175
Number of Poles 3
Breaking Capacity 100 kA @ 480 VAC; 125 kA @ 240 VAC; 20 kA @ 250 VDC; 50 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 4-4/0
Standards Met RoHS Compliant

$11,530.00

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 60 Amp, 600Y/347 VAC, 3 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 100 kA at 240 VAC, 65 kA at 480 VAC, 25 kA at 600Y/347 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41397100
Brand: Square D
Model #: BJA36060
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 60
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 65 kA @ 480 VAC; 25 kA @ 600Y/347 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Reset Actuator Type Toggle Switch

$2,202.66

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 35 Amp, 480Y/277 Volt, 2 Pole, Clip Mount C60BP - Branch Protection Circuit Breaker - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2, 18-3 AWG


Item #: 46119582
Brand: Schneider Electric
Model #: M9F43235
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60BP - Branch Protection
Amperage 35
Number of Poles 2
Breaking Capacity 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 14 kA @ 240 VAC; 10 kA @ 125 VDC; 10 kA @ 480Y/277 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 480Y/277 V
Wire Size (AWG) 18-2; 18-3
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 4.0600
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 1.4200
For Use With OEM Panel
Standards Met UL 489; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$261.68

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 100 Amp, 600Y/347 VAC, 2 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 480 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41399551
Brand: Square D
Model #: BDA261002
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 100
Number of Poles 2
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 480 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type Toggle Switch

$1,120.04

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 4-4/0 AWG


Item #: 54541032
Brand: Square D
Model #: JJL36150
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 20 kA @ 250 VDC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 4-4/0
Standards Met RoHS Compliant

$8,262.24

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 32 Amp, 440 VAC, 1 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2 AWG, 76mm Deep x 81mm High x 18mm Wide


Item #: 56787005
Brand: Schneider Electric
Model #: M9F14132
Exact Tooling IR#: 04

Features and Benefits

Magnetic tripping mechanisms are designed with a solenoid (electromagnet), which will quickly disconnect in case of a short circuit or overload. They are not greatly affected by extreme environmental conditions, but are sensitive to low-overloads.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 32
Number of Poles 1
Breaking Capacity 15 kA @ 230/240 VAC; 30 kA @ 130 VAC; 4 kA @ 400/415 VAC
Tripping Mechanism Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-35
Wire Size (AWG) 18-2
Durability 10000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 18
Overall Width (Decimal Inch) 0.7100
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$174.37

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 110 Amp, 600Y/347 VAC, 3 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC, 14 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG


Item #: 41394040
Brand: Square D
Model #: BDL36110
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 110
Number of Poles 3
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 277 VAC; 14 kA @ 600Y/347 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type Toggle Switch

$1,536.35

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 225 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56743305
Brand: Square D
Model #: JJL36225ABSOLW
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 225
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$11,144.35

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 6 Amp, 440 VAC, 3 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4 AWG, 76mm Deep x 81mm High x 54mm Wide


Item #: 56838162
Brand: Schneider Electric
Model #: M9F12306
Exact Tooling IR#: 04

Features and Benefits

Magnetic tripping mechanisms are designed with a solenoid (electromagnet), which will quickly disconnect in case of a short circuit or overload. They are not greatly affected by extreme environmental conditions, but are sensitive to low-overloads.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 6
Number of Poles 3
Breaking Capacity 10 kA @ 400-415 VAC; 20 kA @ 230-240 VAC; 6 kA @ 440 VAC
Tripping Mechanism Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-25
Wire Size (AWG) 18-4
Durability 10000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 54
Overall Width (Decimal Inch) 2.1300
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$418.41

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 32 Amp, 440 VAC, 4 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2 AWG, 76mm Deep x 81mm High x 72mm Wide


Item #: 56838352
Brand: Schneider Electric
Model #: M9F14432
Exact Tooling IR#: 04

Features and Benefits

Magnetic tripping mechanisms are designed with a solenoid (electromagnet), which will quickly disconnect in case of a short circuit or overload. They are not greatly affected by extreme environmental conditions, but are sensitive to low-overloads.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 32
Number of Poles 4
Breaking Capacity 10 kA @ 440 VAC; 15 kA @ 400-415 VAC; 30 kA @ 230-240 VAC
Tripping Mechanism Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-35
Wire Size (AWG) 18-2
Durability 10000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 72
Overall Width (Decimal Inch) 2.8347
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$715.50

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 250 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 56742190
Brand: Square D
Model #: JJL36250CU44X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 250
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 3/0

$14,232.66

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 90 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56747579
Brand: Square D
Model #: HDL36090SA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 90
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$3,169.08

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 200 Amp, 250 VDC, 600 VAC, 2 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 54522172
Brand: Square D
Model #: JGL26200
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 2
Breaking Capacity 18 kA @ 600 VAC; 20 kA @ 250 VDC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0

$3,328.28

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 30 Amp, 240 VAC, 1 Pole, Bolt On Miniature Circuit Breaker - 14-8 AWG


Item #: 69668671
Brand: Square D
Model #: QOB130HID
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 30
Number of Poles 1
Terminal Connection Type Pressure Plate
Mounting Type Bolt-on
Voltage 240 VAC
Wire Size (AWG) 14-8
Standards Met CSA; RoHS Compliant; UL Listed

$62.57

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 100 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 54527908
Brand: Square D
Model #: HLL36100
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 100
Number of Poles 3
Breaking Capacity 100 kA @ 480 VAC; 125 kA @ 240 VAC; 20 kA @ 250 VDC; 50 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0
Standards Met RoHS Compliant

$4,789.73

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It