Schneider Electric - 0.50 Amp, 1 Pole, Backplate, Clip, DIN Rail Mount Circuit Protector - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 67mm Deep x 74mm High x 15mm Wide


Item #: 69528057
Brand: Schneider Electric
Model #: GB2CB05
Exact Tooling IR#: 04

Features and Benefits

Circuit protectors are designed for protecting relays, motors, heaters, transformers, solenoids and semiconductors from short circuiting. They protect by monitoring the flow of electricity and detecting any imbalances in the electrical device.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Circuit Protector
Amperage 0.50
Number of Poles 1
Breaking Capacity 1 kA @ 48 VDC; 1.5 kA @ 24 VDC; 50 kA @ 110 VAC; 50 kA @ 230/240 VAC
Tripping Mechanism Thermal-Magnetic
Mounting Type Backplate; Clip; DIN Rail Mount
Durability 8000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 67
Overall Height (mm) 74
Overall Width (mm) 15
Reset Actuator Type Toggle Switch

$63.11

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Tripp-Lite - 12 Outlets, 120 VAC20 Amps, 15' Cord, Power Outlet Strip - Clip Mount, Hardwire NEMA Configuration, 36" Strip


Item #: 07065956
Brand: Tripp-Lite
Model #: PS3612-20HW
Exact Tooling IR#: 04

Product Specifications
Amperage 20
Voltage 120 VAC
Number of Outlets 12
Material Aluminum
Mounting Type Clip
Strip Length (Decimal Inch) 36
Cord Length (Feet) 15
NEMA Configuration Hardwire
Overall Depth (Decimal Inch) 36
Color Silver
Overall Height (Decimal Inch) 1-1/2
Overall Width (Decimal Inch) 1-1/2
Recommended Environment Industrial
Trip Reset Manual

$89.18

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Wiremold - 5 Outlets, 120 Volts, 15 Amps, Power Outlet Strip - 1 Circuit, Raceway Mount, 5-15P NEMA Configuration, 5' Strip


Item #: 09847187
Brand: Wiremold
Model #: V20IG512
Exact Tooling IR#: 04

Product Specifications
Amperage 15
Voltage 120 V
Number of Outlets 5
Material Steel
Mounting Type Raceway
Strip Length (Feet) 5
Cord Length (Feet) 0
NEMA Configuration 5-15P
Color Ivory
Number of Circuits 1
Outlet Spacing (mm) 305
Outlet Spacing (Inch) 12

$134.36

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 200 Amp, 600 VAC, 6 Pole Nonfused Safety Switch - NEMA 12, 3, 3R, 4 & 4X, 150 hp at 600 VAC (Triple Phase), 6PST Contact Form


Item #: 56753544
Brand: Square D
Model #: HU664DS
Exact Tooling IR#: 04

Product Specifications
NEMA Enclosure Rating 12; 3; 3R; 4; 4X
Fused NonFused
Number of Poles 6
Amperage 200
Voltage 600 VAC
Horsepower at 3 Phase 150 @ 600 VAC
Contact Form 6PST
Standards Met RoHS Compliant; UL Listed

$47,535.93

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 600 Amp, 600 VAC, 3 Pole, Plug In, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 3/0 AWG, 5 Inch Deep x 7.52 Inch High x 4.12 Inch Wide


Item #: 56765027
Brand: Square D
Model #: LJP36600U44X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 600
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Plug-in; Unit Mount
Voltage 600 VAC
Wire Size (AWG) 3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Height (Decimal Inch) 7.5200
Overall Width (Decimal Inch) 4.1200
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$22,840.31

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Tripp-Lite - 8 Outlets, 120 VAC15 Amps, 8' Cord, Power Outlet Strip - Floor, Keyhole Mount, 5-15 NEMA Configuration, 1-3/4" Strip


Item #: 41633504
Brand: Tripp-Lite
Model #: SK6-6/SPIKEBAR
Exact Tooling IR#: 04

Product Specifications
Amperage 15
Voltage 120 VAC
Number of Outlets 8
Material Plastic
Mounting Type Floor; Keyhole
Strip Length (Decimal Inch) 1-3/4
Cord Length (Feet) 8
NEMA Configuration 5-15
Overall Depth (Decimal Inch) 1-3/4
Color White
Overall Height (Decimal Inch) 13
Overall Width (Decimal Inch) 2-3/4
Trip Reset Manual

$74.90

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 45 Amp, 480Y/277 VAC, 3 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41399163
Brand: Square D
Model #: BDA34045Y
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 45
Number of Poles 3
Breaking Capacity 25 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 480Y/277 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type Toggle Switch

$1,022.36

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 20 Amp, 277 Volt, 1 Pole, Clip Mount C60BP - Branch Protection Circuit Breaker - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG


Item #: 46119368
Brand: Schneider Electric
Model #: M9F44120
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60BP - Branch Protection
Amperage 20
Number of Poles 1
Breaking Capacity 3 kA @ 415 VAC; 10 kA @ 240 VAC; 20 kA @ 60 VDC; 10 kA @ 277 VAC; 14 kA @ 240 VAC; 14 kA @ 120 VAC; 10 kA @ 60 VDC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 277 V
Wire Size (AWG) 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 4.0600
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 0.7100
For Use With OEM Panel
Standards Met UL 489; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$116.07

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 45 Amp, 480Y/277 Volt, 2 Pole, Clip Mount C60BP - Branch Protection Circuit Breaker - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2, 18-3 AWG


Item #: 46120671
Brand: Schneider Electric
Model #: M9F42245
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60BP - Branch Protection
Amperage 45
Number of Poles 2
Breaking Capacity 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 10 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 480Y/277 V
Wire Size (AWG) 18-2; 18-3
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 4.0600
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 1.4200
For Use With OEM Panel
Standards Met UL 489; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$261.68

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Tripp-Lite - 6 Outlets, 120 VAC15 Amps, 8' Cord, Power Outlet Strip - Floor, Keyhole Mount, 5-15 NEMA Configuration, 1.23" Strip


Item #: 91399873
Brand: Tripp-Lite
Model #: TLP608TEL
Exact Tooling IR#: 04

Product Specifications
Amperage 15
Voltage 120 VAC
Number of Outlets 6
Material Plastic
Mounting Type Floor; Keyhole
Strip Length (Decimal Inch) 1.2300
Cord Length (Feet) 8
NEMA Configuration 5-15
Overall Depth (Decimal Inch) 1.2300
Color White
Overall Height (Decimal Inch) 10.8000
Overall Width (Decimal Inch) 1.8500
Trip Reset Manual

$45.22

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 2 Inch Hub Diameter, Load Center Conduit Hub - For Use with Type BR Load Center


Item #: 00104745
Brand: Eaton Cutler-Hammer
Model #: DS200H1
Exact Tooling IR#: 04

Product Specifications
Accessory Type Conduit Hub
Hub Diameter (mm) 50.80
Hub Diameter (Decimal Inch) 2
For Use With Type BR Load Center

$116.75

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 25 Amp, 440 VAC, 2 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4 AWG, 76mm Deep x 81mm High x 36mm Wide


Item #: 49755812
Brand: Schneider Electric
Model #: M9F11225
Exact Tooling IR#: 04

Features and Benefits

Magnetic tripping mechanisms are designed with a solenoid (electromagnet), which will quickly disconnect in case of a short circuit or overload. They are not greatly affected by extreme environmental conditions, but are sensitive to low-overloads.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 25
Number of Poles 2
Breaking Capacity 10 kA @ 400-415 VAC; 20 kA @ 230-240 VAC; 6 kA @ 440 VAC
Tripping Mechanism Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-25
Wire Size (AWG) 18-4
Durability 10000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 36
Overall Width (Decimal Inch) 1.4200
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$269.84

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Wiremold - 8 Outlets, 120 Volts, 15 Amps, 15' Cord, Power Outlet Strip - 1 Circuits, Rack Mount, 5-15R NEMA Configuration, 19" Strip, cULus, UL Listed File 1449


Item #: 62140876
Brand: Wiremold
Model #: R8BZ-15
Exact Tooling IR#: 04

Product Specifications
Amperage 15
Voltage 120 V
Number of Outlets 8
Material Steel
Mounting Type Rack
Strip Length (Decimal Inch) 19
Cord Length (Feet) 15
Cord Length (Meters) 4.60
NEMA Configuration 5-15R
Color Black
Number of Circuits 1
Outlet Spacing (Inch) 1-1/2
Standards Met cULus; UL Listed File 1449

$290.72

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 60 Amp, 600 VAC, 3 Pole Nonfused Safety Switch - NEMA 3R, 30 hp at 600 VAC (Single Phase), 60 hp at 600 VAC (Triple Phase)


Item #: 56754500
Brand: Square D
Model #: HU362RBEI
Exact Tooling IR#: 04

Product Specifications
NEMA Enclosure Rating 3R
Fused NonFused
Number of Poles 3
Amperage 60
Voltage 600 VAC
Horsepower at 1 Phase 30 @ 600 VAC
Horsepower at 3 Phase 60 @ 600 VAC
Contact Configuration NO/NC
Standards Met UL Listed

$1,599.96

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 50 Amp, 120/240 VAC, 3 Pole, Plug In Type CH Circuit Breaker - Thermal Magnetic Trip, 10 kA Breaking Capacity, 14-6 AWG


Item #: 00104984
Brand: Eaton Cutler-Hammer
Model #: CH350
Exact Tooling IR#: 04

Features and Benefits

Type CH circuit breakers are designed to trip cuircuits in severe conditions. They are constructed with thermal-magnetic trip curve that avoids nuisance tripping on mild overloads.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Type CH Circuit Breaker
Amperage 50
Number of Poles 3
Breaking Capacity 10 kA
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Mounting Type Plug-in
Voltage 120/240 VAC
Wire Size (AWG) 14-6
Standards Met Federal Specification W-C-375; UL 489
Reset Actuator Type Handle

$306.60

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 15 Amp, 125 VDC, 240 VAC, 60 VDC, 3 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 123mm High x 54mm Wide


Item #: 56785678
Brand: Schneider Electric
Model #: 60295
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 15
Number of Poles 3
Breaking Capacity 10 kA @ 240 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 6 kA @ 440 VAC
Tripping Mechanism Thermal-Magnetic
Mounting Type DIN Rail Mount; Fixed Mount
Voltage 125 VDC; 240 VAC; 60 VDC
Durability 20000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (mm) 73
Overall Height (mm) 123
Overall Width (mm) 54
Standards Met CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type Handle

$527.19

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Woods PRO - 9 Outlets, 125 Volts, 15 Amps, 3' Cord, Power Outlet Strip - Keyhole Mount, 5-15 NEMA Configuration, 36-1/2" Strip, cULus


Item #: 32202418
Brand: Woods PRO
Model #: 5153
Exact Tooling IR#: 04

Product Specifications
Amperage 15
Voltage 125 V
Number of Outlets 9
Material Metal
Mounting Type Keyhole
Strip Length (Decimal Inch) 36-1/2
Cord Length (Feet) 3
NEMA Configuration 5-15
Color Yellow
Recommended Environment Industrial
Standards Met cULus

$53.28

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - Safety Switch Fuse Clip Kit - For Use with Heavy Duty Safety Switches


Item #: 69647949
Brand: Square D
Model #: DRK30
Exact Tooling IR#: 04

Product Specifications
Switch Accessory Type Fuse Clip Kit
For Use With Heavy-Duty Safety Switches

$27.92

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 30 Amp, 240 VAC, 3 Pole Fused Safety Switch - NEMA 3R, 3 Phase, 1-1/2 to 3 hp at 240 VAC (Single Phase), 3 to 7-1/2 hp at 240 VAC (Triple Phase), 3PST Contact Form


Item #: 00438283
Brand: Eaton Cutler-Hammer
Model #: DG321NRB
Exact Tooling IR#: 04

Product Specifications
NEMA Enclosure Rating 3R
Fused Fused
Number of Poles 3
Amperage 30
Voltage 240 VAC
Horsepower at 1 Phase 1-1/2 to 3 HP @ 240 VAC
Horsepower at 3 Phase 3 to 7-1/2 HP @ 240 VAC
Number of Phases 3
Contact Form 3PST
Number of Wires 4
Overall Height (mm) 274.60
Overall Height (Decimal Inch) 10.8100
Overall Width (mm) 162.10
Overall Width (Decimal Inch) 6.3800
Overall Width (Inch) 6-5/8
Overall Depth (Decimal Inch) 3-3/4
Overall Depth (mm) 95.20
Standards Met NEMA Std KS-1; UL 98; UL Listed File E5239

$393.98

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 30 Amp, 120/240 VAC, 1 Pole, DIN Rail Mounted Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 240 VAC Breaking Capacity, 14-2 AWG, 76mm Deep x 81mm High x 18mm Wide


Item #: 56838956
Brand: Schneider Electric
Model #: 60232
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 30
Number of Poles 1
Breaking Capacity 10 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 120/240 VAC
Wire Size (sq mm) 1-35
Wire Size (AWG) 14-2
Durability 4000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 18
Overall Width (Decimal Inch) 0.7100
Standards Met CE Marked; CSA C22.2 No. 5.1 Circuit Breakers: File No. 179014; HID (High Intensity Discharge) Rated; IEC 60947-2; UL 489 Circuit Breakers: File No. E215117; UL Listed for SWD Applications
Reset Actuator Type Handle

$175.73

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It