We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

Lighting & Electrical Products - Contactors & Starters For Sale | Makers Industrial Supply - (4027 Products)


Schneider Electric - 9 to 38 Amp, Contactor Coil - For Use with LC1D09-D38, LC1DT20-DT40 and TeSys D


Item #: 69663888
Brand: Schneider Electric
Model #: LXD1G7
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Coil
For Use With LC1D09-D38; LC1DT20-DT40; TeSys D
Compatible Contactor Amperage 9-38

$50.86

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Contactor Control Block - For Use with TeSys D D80/D95


Item #: 49787559
Brand: Schneider Electric
Model #: LA9D11567
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Control Block
For Use With TeSys D D80/D95

$5.72

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 440 Coil VAC at 50 Hz, 480 Coil VAC at 60 Hz, 540 Amp, NEMA Size 6, Nonreversible Open Enclosure NEMA Motor Starter - 3 Phase hp: 150 at 200 VAC, 200 at 230 VAC, 400 at 460 VAC, 400 at 575 VAC


Item #: 56824543
Brand: Square D
Model #: 8536SHO2V06H30
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 540
NEMA Size 6
Coil Voltage 440 VAC @ 50 Hz; 480 VAC @ 60 Hz
Enclosure Type Open
Action NonReversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 150 @ 200 VAC; 200 @ 230 VAC; 400 @ 460 VAC; 400 @ 575 VAC
Standards Met CSA; NEMA; UL Listed

$33,057.54

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - Contactor Thermal Unit - For Use with B Series


Item #: 69650323
Brand: Square D
Model #: B1.30
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Thermal Unit
For Use With B Series

$40.63

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - Contactor Auxiliary Contact Kit - For Use with Class 8965 Type DPR Contactors


Item #: 69665339
Brand: Square D
Model #: 9999DD20
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Auxiliary Contact Kit
For Use With Class 8965 Type DPR Contactors

$49.65

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Contactor Coil - For Use with LC1F185, LC1F225 and TeSys F


Item #: 49755747
Brand: Schneider Electric
Model #: LX9FG220
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Coil
For Use With LC1F185; LC1F225; TeSys F

$132.77

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 80 to 95 Amp, Contactor Coil - For Use with LC1D80, LC1D95 and TeSys D


Item #: 69664514
Brand: Schneider Electric
Model #: LX1D6T6
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Coil
For Use With LC1D80; LC1D95; TeSys D
Compatible Contactor Amperage 80; 95

$68.30

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 110 Coil VAC at 50 Hz, 120 Coil VAC at 60 Hz, 18 Amp, Nonreversible Open Enclosure NEMA Motor Starter - 3 Phase hp: 3 at 200 VAC, 3 at 230 VAC, 5 at 460 VAC, 5 at 575 VAC


Item #: 56815814
Brand: Square D
Model #: 8536SBO2V02SX10
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 18
NEMA Size 0
Coil Voltage 110 VAC @ 50 Hz; 120 VAC @ 60 Hz
Enclosure Type Open
Action NonReversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 3 @ 200 VAC; 3 @ 230 VAC; 5 @ 460 VAC; 5 @ 575 VAC
Standards Met CSA; NEMA; RoHS Compliant; UL Listed

$971.38

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 110 Coil VAC at 50 Hz, 120 Coil VAC at 60 Hz, 27 Amp, NEMA Size 1, Nonreversible Enclosed Enclosure NEMA Motor Starter - 3 Phase hp: 10 at 460 VAC, 10 at 575 VAC, 7-1/2 at 200 VAC, 7-1/2 at 230 VAC, 1 Enclosure Rating


Item #: 69524635
Brand: Square D
Model #: 8536SCG3V02H30S
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 1 refers to enclosures constructed for indoor use. They provide a degree of protection from falling and other solid objects entering the enclosure.
Product Specifications
Amperage 27
NEMA Size 1
Coil Voltage 110 VAC @ 50 Hz; 120 VAC @ 60 Hz
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 1
Horsepower at 3 Phase 10 @ 460 VAC; 10 @ 575 VAC; 7-1/2 @ 200 VAC; 7-1/2 @ 230 VAC
Standards Met CSA; NEMA; RoHS Compliant; UL Listed

$656.23

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 3 to 7 Amp, Contactor Current Limiting Module - For Use with FA Frame/Mag-Gard Circuit Breaker


Item #: 56825268
Brand: Square D
Model #: 9999CLM1
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Current Limiting Module
For Use With FA Frame/Mag-Gard Circuit Breaker
Compatible Contactor Amperage 3-7

$499.99

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Contactor Coil - For Use with LC1F185, LC1F225 and TeSys F


Item #: 56806383
Brand: Schneider Electric
Model #: LX4FG220
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Coil
For Use With LC1F185; LC1F225; TeSys F

$164.13

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Contactor Suppressor Module - For Use with 3 Pole LC1D80-D150 Contactor and TeSys D


Item #: 69526887
Brand: Schneider Electric
Model #: LAD4RCG
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Suppressor Module
For Use With 3 Pole LC1D80-D150 Contactor; TeSys D

$32.64

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 18 Amp, Open Enclosure NEMA Motor Starter


Item #: 49789449
Brand: Square D
Model #: 8810SBO4V02S
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.

Product Specifications

18 Amp, Open Enclosure NEMA Motor Starter -
Amperage 18
NEMA Size 0
Enclosure Type Open
Standards Met NEMA; UL Listed

$2,142.82

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Contactor Interlock - For Use with LC1D115, LC1D150 and TeSys D


Item #: 69527885
Brand: Schneider Electric
Model #: LA9D11502
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Interlock
For Use With LC1D115; LC1D150; TeSys D

$101.00

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 9 to 38 Amp, Contactor Coil - For Use with LC1D09-D38, LC1DT20-DT40 and TeSys D


Item #: 49754492
Brand: Schneider Electric
Model #: LXD1E7
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Coil
For Use With LC1D09-D38; LC1DT20-DT40; TeSys D
Compatible Contactor Amperage 9-38

$50.58

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Contactor Suppressor Module - For Use with 3 Pole LC1D80 Contactor and TeSys D


Item #: 49787658
Brand: Schneider Electric
Model #: LA4DC1U
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Suppressor Module
For Use With 3 Pole LC1D80 Contactor; TeSys D

$32.52

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 120 Coil VAC, 9 Amp, Nonreversible Open Enclosure NEMA Motor Starter - 3 Phase hp: 1-1/2 at 200 VAC, 1-1/2 at 230 VAC, 2 at 460 VAC, 2 at 575 VAC


Item #: 56816374
Brand: Schneider Electric
Model #: T36AN13G7
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 9
NEMA Size 00
Coil Voltage 120 VAC
Enclosure Type Open
Action NonReversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 1-1/2 @ 200 VAC; 1-1/2 @ 230 VAC; 2 @ 460 VAC; 2 @ 575 VAC
Standards Met CE; CSA; UL Listed

$652.14

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 110 Coil VAC at 50 Hz, 120 Coil VAC at 60 Hz, 135 Amp, NEMA Size 4, Reversible Open Enclosure NEMA Motor Starter - 3 Phase hp: 100 at 460 VAC, 100 at 575 VAC, 40 at 200 VAC, 50 at 230 VAC


Item #: 56813017
Brand: Square D
Model #: 8736SFO1V02S
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Reversing starters are designed with three individual lines that connect to and run voltage through a motor. Each line alternates in a sequence as they reach their voltage peak. They are used to reverse the rotation of a motor.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 135
NEMA Size 4
Coil Voltage 110 VAC @ 50 Hz; 120 VAC @ 60 Hz
Enclosure Type Open
Action Reversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 100 @ 460 VAC; 100 @ 575 VAC; 40 @ 200 VAC; 50 @ 230 VAC
Standards Met CSA; NEMA; UL Listed

$14,419.54

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Contactor Suppressor Module - For Use with 3 Pole LC1D80-D150 Contactor


Item #: 56804230
Brand: Schneider Electric
Model #: LA4DA1G
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Suppressor Module
For Use With 3 Pole LC1D80-D150 Contactor

$39.83

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 220 Coil VAC at 50 Hz, 240 Coil VAC at 60 Hz, 27 Amp, NEMA Size 1, Reversible Open Enclosure NEMA Motor Starter - 3 Phase hp: 10 at 460 VAC, 10 at 575 VAC, 7-1/2 at 200 VAC, 7-1/2 at 230 VAC


Item #: 56824758
Brand: Square D
Model #: 8736SCO7V03
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Reversing starters are designed with three individual lines that connect to and run voltage through a motor. Each line alternates in a sequence as they reach their voltage peak. They are used to reverse the rotation of a motor.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 27
NEMA Size 1
Coil Voltage 220 VAC @ 50 Hz; 240 VAC @ 60 Hz
Enclosure Type Open
Action Reversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 10 @ 460 VAC; 10 @ 575 VAC; 7-1/2 @ 200 VAC; 7-1/2 @ 230 VAC
Standards Met CSA; NEMA; RoHS Compliant; UL Listed

$1,877.73

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It